Rockwell Automation 2755 AtomScan Bar Code Reader User Manual
Page 125

Application Examples
E–9
Publication 2755-6.9
Configuration Codes for the SLC 5/03 and SLC 5/04 Controllers
After making the necessary connections, set the reader to the settings
in the table below to allow the reader to communicate with the SLC
5/03 or SLC 5/04 controllers.
Description
Menu Setting
Serial Command Setting
Preamble
Disable
<Kd0>
Postamble
Enable Control J
<Kel,^M,^J>
Baud Rate
9600
Parity
None
Stop Bits
One
<Ka4,0,0,1>
Data Bits
8
SLC 5/03 and SLC 5/04 Controllers Setup
You need to configure the SLC 5/03 and SLC 5/04 controllers.
Follow the steps starting below or refer to the following publications:
•
SLC 500 Modular Hardware Style Installation and Operation
Manual (Publication No. 1747-6.2)
•
SLC 500 and MicroLogix
t 1000 Instruction Set Reference
Manual (Publication No. 1747-6.15)
•
Advanced Programming Software User Manual
(Publication No. 9399-APSUM-11.15.95)
1. Set the SLC Channel 0 to User in the Channel 0 Configuration
screen