5–27
Configuring Your Reader
Publication 2755-6.9
Function
Command
Parameter
Format
Relay 1
Kv
<Kvoutput on,polarity,pulse width>
Relay 2
Kw
<Kwoutput on,polarity,pulse width>
Bar Code Output
Kl
<Klstatus,when to output>
No Read Message
Kk
<Kkstatus,output>
Beeper
Ku
<Kustatus,volume>
Laser On/Off
KC
<KCstatus>
Scanner Output
Serial Verification
KS
<K
S
serial command status,serial
command beep status,control/hex
output>
Scanner Output Status
Request
KX
<KX?>
Partial Output
KY
<KYstatus,start position,length>
Scanner Type
KP
<KPdensity>
Scans per Second
KE
<KEspeed>
Auto Gain Control
KD
<KDgain adjustment,AGC
sampling,tracking>
Scanner Setup
Bad Bar Code
Message
KM
<KMstatus,message>
Scanner Setup
No Bar Code Message
KN
<KNstatus,message>
No Object Bar Code
Message
KO
<KOstatus,message>
Scanner Setup Status
Request
KU
<KU?>
The sections that follow describe the commands listed in the table