Rockwell Automation 2755 AtomScan Bar Code Reader User Manual

Page 72

Advertising
background image

5–27

Configuring Your Reader

Publication 2755-6.9

Function

Command

Parameter

Format

Relay 1

Kv

<Kvoutput on,polarity,pulse width>

Relay 2

Kw

<Kwoutput on,polarity,pulse width>

Bar Code Output

Kl

<Klstatus,when to output>

No Read Message

Kk

<Kkstatus,output>

Beeper

Ku

<Kustatus,volume>

Laser On/Off

KC

<KCstatus>

Scanner Output

Serial Verification

KS

<K

S

serial command status,serial

command beep status,control/hex
output>

Scanner Output Status
Request

KX

<KX?>

Partial Output

KY

<KYstatus,start position,length>

Scanner Type

KP

<KPdensity>

Scans per Second

KE

<KEspeed>

Auto Gain Control

KD

<KDgain adjustment,AGC
sampling,tracking>

Scanner Setup

Bad Bar Code
Message

KM

<KMstatus,message>

Scanner Setup

No Bar Code Message

KN

<KNstatus,message>

No Object Bar Code
Message

KO

<KOstatus,message>

Scanner Setup Status
Request

KU

<KU?>

The sections that follow describe the commands listed in the table