5 - configuring your reader, Menu configuration, Configuring your reader – Rockwell Automation 2755 AtomScan Bar Code Reader User Manual

Page 46: Chapter

Advertising
background image

Chapter

5

Publication 2755-6.9

Configuring Your Reader

This chapter describes the configuration options for the readers.
Items include:

menu configuration

serial configuration

decode test

adjusting reader parameters

You can change the reader’s configuration through the use of menus.
Follow the steps starting below to change the reader’s configuration.

To Access the Reader Configuration Main Menu

1. Make sure you have a terminal utility software running on your

configuration device.

2. Check the following communication port parameters on your

configuration device. Make sure the parameters match the
settings listed below. If the parameters do not match,
communication between the reader and configuration device will
not occur.

Description

Default Setting

Baud Rate

9600

Parity

Even

Stop Bits

One

Data Bits

7

3. Read a test bar code to verify that the default settings are correct

(i.e., the reader is communicating with the host device. The bar
code value will appear on the screen.). If you cannot read a test
bar code:

verify that you are using the correct communication cable or

default the reader directly or via the interface box. Refer to
chapter 6 for information regarding defaulting the readers.

Also refer to chapter 7 for information regarding troubleshooting
the readers.

Menu Configuration

Advertising