5–20

Configuring Your Reader

Publication 2755-6.9

Scanner Output Menu

The Scanner Output menu, shown below, allows you to configure the
reader’s output. Default settings are in bold type face.

Bar code output data and no read messages are transmitted on pin 2
under conditions set principally in Bar Code Output.

Relay pulses are transmitted via pins 7 and 14 (Relay-1 and Relay-2,
respectively) and individually configured under conditions set in
Relay-1 and Relay-2.

Relay-1 and Relay-2 can allow simultaneous output under
individually programmed conditions.

Output On

–

Mismatch or No Read

–

Match
(or Good Read)

–

Mismatch

–

No Read

Polarity

–

Negative

–

Positive

Pulse Width
(in 10 ms incs)

➀

–

50 ms

–

User Definable
(0 to 255)

Beeper Status

–

On Good

–

On No Read

Beeper Volume

–

Level 4

–

Level 5

–

Off

–

Level 1

–

Level 2

–

Level 3

Full Screens

–

Enabled

–

Disabled

Laser On/Off

–

Disabled

–

Enabled

Scanner Output

Bar Code
Output

–

Good Read

–

Disabled

–

Match

–

Mismatch

When to Output

–

As Soon As
Possible

–

End Of Read
Cycle

No Read Message
7 digits

–

No Read

–

User Definable
(ASCII char.)

No Read Output

–

Enabled

–

Disabled

Relay-1

Relay-2

Partial Output

Length

–

63

–

User Definable
(1 to 63)

Status

–

Disabled

–

Enabled

Start Position

–

1

–

User Definable
(1 to 63)

➀

Divide the number entered on the command line by 100 for time in seconds.