5–29

Configuring Your Reader

Publication 2755-6.9

Postamble. You can enter one or two postamble characters except
a null (00H).

Command

Parameter

Format

Example

Status

0 = Disabled

Ke

<Kestatus,postamble

To disable Postamble, press

[<Ke0>]

1 = Enabled

Ke

character(s)>

[<Ke0>]

.

LRC

Command

Parameter

Format

Example

Status

0 = Disabled

Kc

<Kcstatus>

To enable LRC, press

[<Kc1>]

.

1 = Enabled

Kc

<Kcstatus>

To enable LRC, press

[<Kc1>]

.

Response Timeout. You can use any number from zero to 65,000.
(A zero causes an indefinite wait.) The default is 12 ms.

Parameter

Format

Example

KA

<KAtimeout setting>

To change Response Timeout to 30 ms,
press

[<KA30>]

.

Intercharacter Delay. You can use any number from zero to 255.
The default is zero.

Parameter

Format

Example

KB

<KAtime interval>

To change Intercharacter Delay to
30 ms, press

[<KB30>]

.