Rockwell Automation 2755 AtomScan Bar Code Reader User Manual

Page 87

Advertising
background image

6–2

Hardware Operation

Publication 2755-6.9

Function

Command

Action

<A>

Software Reset (does not save for power-on)

<Ad>

Software Reset/Restore Default

<An>

Software Reset/Read NOVRAM

Program Management

<D>

Enter Configuration Mode

Program Management

<Z>

Software Reset/Save Parameters for Power-on

<Zd>

Restore/Save Default Configuration for Power-on

<Zp>

Save Scanner Type, SPS, and Gain for Power-on

<H>

Enable Laser Scanning (Laser On)

<I>

Disable Laser Scanning (Laser Off)

<KE>

Motor On

Device Control

<KF>

Motor Off

<L1>

Relay-1 Pulse

<L2>

Relay-2 Pulse

<P>

Autodiscriminate All Codes

<Q>

Enable Code 39 Only

Code Types

<R>

Enable Codabar Only

<S>

Enable I 2 of 5 Only

<N>

No Read Counter

<O>

No Read Counter Reset

<T>

Trigger Counter

<U>

Trigger Counter Reset

Counter

<V>

Match Code/Good Read Counter

<W>

Match Code/Good Read Counter Reset

<X>

Mismatch Counter

<Y>

Mismatch Counter Reset

<C>

Enter Decode Rate Test

Test

<Ce>

Enter Extended Decode Rate Test

Test

<J>

Exit Decode Rate Test; Exit Extended Decode Rate Test

<#>

Display Software Part Number

<!>

Display Checksum of EPROM

<?>

Show Scanner Status

Status

<?1>

Show Software Status (Send Status Byte, Part Number, and ROM
Checksum. Display NOVRAM Checksum at Power Up, then Display
Current NOVRAM Checksum)

<E>

Enable Match Code Option

<F>

Disable Match Code Option

<G>

Store Next Label Scanned as Master Label

Master Label

<)XXXX)>

Download Master Label Information

<)>

Request Master Label Information

<))>

Delete Master Label Information

The command can also be set in the configuration menu or with a serial configuration command.