6–2
Hardware Operation
Publication 2755-6.9
Function
Command
Action
<A>
Software Reset (does not save for power-on)
<Ad>
Software Reset/Restore Default
<An>
Software Reset/Read NOVRAM
Program Management
<D>
Enter Configuration Mode
Program Management
<Z>
Software Reset/Save Parameters for Power-on
<Zd>
Restore/Save Default Configuration for Power-on
<Zp>
Save Scanner Type, SPS, and Gain for Power-on
<H>
Enable Laser Scanning (Laser On)
<I>
Disable Laser Scanning (Laser Off)
<KE>
Motor On
Device Control
<KF>
Motor Off
<L1>
Relay-1 Pulse
<L2>
Relay-2 Pulse
<P>
Autodiscriminate All Codes
<Q>
Enable Code 39 Only
➀
Code Types
<R>
Enable Codabar Only
➀
<S>
Enable I 2 of 5 Only
➀
<N>
No Read Counter
<O>
No Read Counter Reset
<T>
Trigger Counter
<U>
Trigger Counter Reset
Counter
<V>
Match Code/Good Read Counter
<W>
Match Code/Good Read Counter Reset
<X>
Mismatch Counter
<Y>
Mismatch Counter Reset
<C>
Enter Decode Rate Test
Test
<Ce>
Enter Extended Decode Rate Test
Test
<J>
Exit Decode Rate Test; Exit Extended Decode Rate Test
<#>
Display Software Part Number
<!>
Display Checksum of EPROM
<?>
Show Scanner Status
Status
<?1>
Show Software Status (Send Status Byte, Part Number, and ROM
Checksum. Display NOVRAM Checksum at Power Up, then Display
Current NOVRAM Checksum)
<E>
Enable Match Code Option
➀
<F>
Disable Match Code Option
➀
<G>
Store Next Label Scanned as Master Label
Master Label
<)XXXX)>
Download Master Label Information
<)>
Request Master Label Information
<))>
Delete Master Label Information
➀
The command can also be set in the configuration menu or with a serial configuration command.