Hardware connections for the plc-5 controllers, Configuration codes for the plc-5 controllers – Rockwell Automation 2755 AtomScan Bar Code Reader User Manual
Page 128
Advertising
![background image](/manuals/580584/128/background.png)
Application Examples
E–12
Publication 2755-6.9
Hardware Connections for the PLC-5 Controllers
The interface box connects to the PLC-5 controllers with an RS-232
cable.
Interface Box
To RS-232 Port
Personal
Computer
Power Supply
To Power Receptacle
RS-232 Cable
RS-232 Null Modem Cable
(Swap pins 2 and 3.)
Reader
OR
To Channel 0 Port
PLC-5
Configuration Codes for the PLC-5 Controllers
After making the necessary connections, set the reader to the settings
in the table below to allow the reader to communicate with the
PLC-5 controllers.
Description
Menu Setting
Serial Command Setting
Preamble
Disable
<Kd0>
Postamble
Control J
<Kel,^M,^J>
Baud Rate
9600
Parity
None
Stop Bits
One
<Ka4,0,0,1>
Data Bits
8