Introduction to AtomScan

+

Bar Code Readers

Publication 2755-6.9

7.

Apply power to the scanner system.

Reference

After all of your hardware components are installed, apply power to your scanner system. Push the
power button in on the interface box.

Chapter 4

(Installing Your

Hardware)

Front View of the Interface Box

Power Switch

8.

Check the reader defaults.

Reference

Check the following configuration parameters on your host device. (Make sure you have a
Windows

t

terminal utility software on your personal computer.

)

Make sure the defaults match the

settings listed below. If the defaults do not match, communication between the reader and host
device will not occur.

baud rate = 9600

parity = even

stop bits = one

data bits = 7

Chapter 5

(Configuring Your

Reader)

Read a test bar code to verify that the default settings are correct (i.e., the reader is communicating
with the configuration device).