For a sequence on a No Read, refer to the following table. When
disabled, the reader does not sequence (increment or decrement)
on a No Read. When enabled, the reader sequences on every No
Read.

Command

Example

Status

0 = Disabled

If 001, 002, No Read, then search for 003.

1 = Enabled

If 001, 002, No Read, then search for 004.

For a sequence on every mismatch, refer to the following table.
When disabled, if a mismatch is out of sequence by more than 1,
the sequence resumes. When enabled, the reader sequences the
on every mismatch.

Command

Example

Status

0 = Disabled

If 001, 002, 004 (mismatch), then search for 005.

1 = Enabled

If 001, 002, mismatch, then search for 004.

New Master Pin

Command

Parameter

Format

Example

Status

0 = Disabled

Kz

<Kzstatus>

To enable New Master Pin, press

[<Kz1>]

1 = Enabled

Kz

<Kzstatus>

[<Kz1>]

.

Number of Labels. You can use any number between 1 and 6.
The default is 1. The multilabel separator is any valid ASCII
character.

Parameter

Format

Example

KL

<KLnumber, multilabel
separator>

To change Number of Labels to 3, press

[<KL3>]

.

Operations Status Request. Allows you to return the status of
each command in the group.

Parameter

Format

KV

<KV?>

Code Types Commands

Narrow Margins

Command

Parameter

Format

Example

Status

<Konarrow margin

0 = Disabled

Ko

<Konarrow margin
status,symbology ID

To enable Narrow Margins, press

[<Ko1>]

1 = Enabled

Ko

status,symbology ID
status>

[<Ko1>]

.