Rockwell Automation 2755 AtomScan Bar Code Reader User Manual

Page 76

Advertising
background image

5–31

Configuring Your Reader

Publication 2755-6.9

Auxiliary Port

Command

Parameter

Format

Example

Mode

0 = Disabled

1 = Transparent

2 = Half-duplex

3 = Full-duplex

4 = Slave Mode

Baud Rate

0 = 600

1 = 1200

2 = 2400

3 = 4800

4 = 9600

5 = 19200

<Ky mode,baud

To change Auxiliary Port Baud Rate to

6 = 38400

Ky

rate,parity,stop bits,data

To change Auxiliary Port Baud Rate to
2400, press

[<Ky2>]

.

7 = 76800

bits>

[

y

]

8 = 300

Parity

0 = None

1 = Even

2 = Odd

Stop Bits

0 = One

1 = Two

Data Bits

0 = Seven

1 = Eight

Communications Status Request. Allows you to return the status
of each command in the group.

Parameter

Format

KT

<KT?>

Operations Commands

Triggering Mode. The trigger filtering time occurs in 128
microsecond increments. You can use any number between 2 and
255. The default is 78 (approximately 10 seconds).

Command

Parameter

Format

Example

Triggering Mode

0 = Continuous Read

1 = Continuous Read, 1 Output

2 = External Level

Kg

<Kgtriggering mode,filter

To select External edge, press

[<Kg3>]

3 = External Edge

Kg

time>

[<Kg3>]

.

4 = Serial Data

5 = Serial Data and Edge

Advertising