Operations menu, 5–9 configuring your reader, Operations – Rockwell Automation 2755 AtomScan Bar Code Reader User Manual
Page 54

5–9
Configuring Your Reader
Publication 2755-6.9
Operations Menu
The Operations menu, shown below, allows you to set the operations
parameters for the reader. Default settings are in bold type face.
Triggering Mode
–
Read
–
Continuous Read 1
Output
–
External Level
–
External Edge
–
Serial Data
–
Serial Data & Edge
End of
Read Cycle
–
Timeout
–
New Trigger
–
Timeout & New
Trigger
Timeout in 10 ms
incs
➀
–
100
–
0 to 65,535
Serial Trigger
Character
–
^]
–
any ASCII
character
External
Trigger
Level
–
Positive
–
Negative
Number of
Labels
–
1
–
1 to 6
Operations
Trigger Filter
➁
–
78
–
2 to 255
Multilabel
Separator
–
, (comma)
–
any ASCII
character
Good Decode
Reads
–
1
–
1 to 31
New Master
Pin
–
Disabled
–
Enabled
Match Code
Type
–
Disabled
–
Enabled
–
Sequential
–
Wild Card
Match Code
Master
–
(blank)
–
User entry (up
to 64
characters)
Sequential
Matching
–
Increment
–
Decrement
Match Start
Position
–
0
–
0 to 64
Match Length
–
1
–
1 to 64
Wild Card Character
–
* (asterisk)
–
any ASCII character
➀
Divide the number entered on the command line by 100 for time in seconds.
➁
Multiply the number entered on the command line by 128 for time in microseconds, then divide by
1000 for time in milliseconds.