5–37

Configuring Your Reader

Publication 2755-6.9

Beeper

Command

Parameter

Format

Example

Beeper Status

0 = On Good

1 = On No Read

Beeper Volume

0 = Off

To set the beeper for On No Read and

1 = Level 1

Ku

<Kustatus,volume>

set the beeper volume to Off, press

[<Ku1 0>]

2 = Level 2

[<Ku1,0>]

.

3 = Level 3

4 = Level 4

5 = Level 5

Laser On/Off

Command

Parameter

Format

Example

Status

0 = Disabled

KC

<KCstatus>

To enable Laser On/Off, press

[<KC1>]

1 = Enabled

KC

<KCstatus>

[<KC1>]

.

Serial Verification

Command

Parameter

Format

Example

Serial Command Echo Status

0 = Disabled

1 = Enabled

Serial Command Beep Status

<KSserial command

To enable Serial Command Echo Status,

0 = Disabled

KS

status,serial command

To enable Serial Command Echo Status,
Beep status, and Hex Output, press

1 = Enabled

KS

beep status,control/hex

Beep status, and Hex Output, press

[<KS1,1,1>]

.

Control/hex Output

output>

0 = Control

1 = Hex

User Output Status Request. Allows you to return the status of
each command in the group.

Parameter

Format

KX

<KX?>

Partial Label Output. Allows you to transmit a portion of the
label to the host.

Command

Parameter

Format

Example

Status

0 = Disabled

1 = Enabled

To enable Partial Label Output starting

Start Position

KY

<KYstatus,start

To enable Partial Label Output starting
at character 4 and ending at character 8

KY

position,length>

at character 4 and ending at character 8

[<KY1 4 5>]

1 to 63. 1 is the default.

of the string, press

[<KY1,4,5>]

.

Length

1 to 63. 63 is the default.