Rs-232 port – Rockwell Automation 2755 AtomScan Bar Code Reader User Manual
Page 111

Cable Pinouts
B–4
Publication 2755-6.9
RS-232 Port
1
13
14
25
Pin
Signal
Function
1
GND
Chassis ground
2
TXD
Reader transmits data to host device.
3
RXD
Reader receives data from the host device.
4
RTS, TXD, or
RS-485 Enable
Host RS-232 RTS or under software control aux RS-232
TXD, or RS-485 transmitter enable.
5
CTS or RXD
Host RS-232 CTS or under software control aux RS-232
RXD.
6
Output
TTL relay output (5V dc @ 2 mA). Sink is 10 mA and
source is 2 mA.
7
GND
Signal ground
8
Output
TTL relay output (5V dc @ 2 mA). Sink is 10 mA and
source is 2 mA.
9
5 Volts
5 V
10
Input
Trigger input; same as pin 1 of trigger connector.
11
Input
Default configuration pin goes to pin 8 of the reader
connector and the default switch.
12
Not Used
No connection
13
RXB+
Reader receives data from the host device in RS-485 and
RS-422 modes.
14
TXA–
Reader transmits data to host device.
15
Output
Relay contact normally open
16
RXA–
Reader receives data from the host device in RS-485 and
RS-422 modes.
17
Common
Common
18
Not Used
No connection
19
TXB+
Reader transmits data to host device in RS-485 and
RS-422 modes.
20
Not Used
No connection
21
Not Used
No connection
22
GND
Ground
23
Not Used
No connection
24
Not Used
No connection
25
Input
New Master input to pin 12 of the reader connector and