Rockwell Automation 2755 AtomScan Bar Code Reader User Manual

Page 73

Advertising
background image

5–28

Configuring Your Reader

Publication 2755-6.9

Communications Commands

Protocol. If selecting one of the options from 0 to 4
(Point-to-Point, Point-to-Point with RTS/CTS, Point-to-Point
with XON/XOFF, Point-to-Point with RTS/CTS and
XON/XOFF, or Polling Mode D), use the format below.

Command

Parameter

Format

Example

Protocol

0 = Point-to-Point

1 = Point-to-Point with RTS/CTS

To change the Protocol to Polling Mode

2 = Point-to-Point with XON/XOFF

Kf

<Kfprotocol>

To change the Protocol to Polling Mode
D, press

[<Kf4>]

.

3 = Point-to-Point with RTS/CTS and XON/XOFF

[

]

4 = Polling Mode D

If selecting Multidrop (5), you must define an address and append
it to the command string. The address can be from 1 to 50.

Command

Parameter

Format

Example

Protocol

To change the Protocol to Multidrop with

5 = Multidrop

Kf

<Kfprotocol,address>

an address of 33, press

[<Kf5,33>]

.

If selecting User Defined (6) or User Defined Multidrop (7),
complete the format by either choosing new parameters or
concatenating unchanged data fields (separate by commas).

For User Defined, first select Point-to-Point <Kf0> and then User
Defined <Kf6...>. For user Defined Multidrop, first select
Multidrop <Kf5>, then User Defined Multidrop <Kf7...>.

Command

Parameter

Format

Example

Protocol

To select an unpolled ACK/NAK User

6 = User Defined

Kf

<Kfprotocol,RES,address,
REQ,EOT,STX,ETX,ACK,

Defined protocol with LRC disabled,
press

[<Kf0><Kf6,,,,,,,

^F ^U

K 0 ]

7= User Defined Multidrop

NAK>

^F,^U><Kc0>]

. ACK and NAK

will be displayed in the menu

.

<Kf0> nulls the address and <Kc0> disables LRC.

A control character, represented here as two characters (^F or ^U, etc.), is actually a single ASCII
character that is entered on the keyboard by holding down the control key while pressing the
desired letter.

Preamble. You can enter one or two preamble characters except a
null (00H).

Command

Parameter

Format

Example

Status

To enable Preamble with just one

0 = Disabled

Kd

<Kdstatus,preamble

To enable Preamble with just one
character, an FF (form feed), press

1 = Enabled

Kd

character(s)>

character, an FF (form feed), press

[<Kd1,^L>]

.