Reset storage array iscsi baseline, Reset storage array sas phy baseline – Dell PowerVault MD3260i User Manual

Page 240

Advertising
background image

Reset Storage Array iSCSI Baseline

Description

This command resets the iSCSI baseline for the storage array to 0.

Syntax

reset storageArray iscsiStatsBaseline

Parameters

None.

NOTE: This command resets the baseline to 0 for both RAID controller modules in the storage array. The purpose of
resetting both of the RAID controller module baselines is to help ensure that the counts are synchronized between
the RAID controller modules. If one RAID controller module resets but the second RAID controller module does not
reset, the host is informed that the RAID controller modules are out of synchronization. The host is informed by the
time stamps that are reported with the statistics.

Example
-c "reset storageArray iscsiStatsBaseline;"

Reset Storage Array SAS PHY Baseline

Description

This command resets the SAS physical layer (SAS PHY) baseline for all devices except physical disks, and removes the
list of errors from the .csv file. The .csv file is generated by running the save storageArray SASPHYCounts
command.

NOTE: The reset storageArray SASPHYBaseline command clears error counts for all devices except
the physical disks. After running this command, the .csv file continues to list the DrivePHY errors. All other errors
are deleted from the .csv file.

Syntax

reset storageArray SASPHYBaseline

Parameters

None.

240

Advertising