Set session, Description, Syntax – Dell PowerVault MD3260i User Manual

Page 286: Parameters, Additional information

Advertising
background image

element. The capacity of the expandable repository virtual disk is exactly that of the single element. You can increase
the capacity of an expandable repository virtual disk by attaching additional standard virtual disks to it. The composite
expandable repository virtual disk capacity then becomes the sum of the capacities of all of the concatenated standard
virtual disks.
A remote replication group repository virtual disk must satisfy a minimum capacity requirement that is the sum of the
following:

32 MB to support fixed overhead for the remote replication group and for copy-on-write processing.

Capacity for rollback processing, which is 1/5000th of the capacity of the base virtual disk.

The minimum capacity is enforced by the RAID controller module firmware and the MD storage management software.

Set Session

Description

This command defines how you want the current script engine session to run.

Syntax

set session errorAction=(stop | continue)

password=”storageArrayPassword

performanceMonitorInterval=intervalValue

performanceMonitorIterations=iterationValue

Parameters

Parameter

Description

errorAction

How the session responds if an error is encountered
during processing. You can choose to stop the session if
an error is encountered, or you can continue the session
after encountering an error. The default value is stop.
(This parameter defines the action for execution errors,
not syntax errors. Some error conditions might override
the continue value.)

password

The password for the storage array. Enclose the password
in double quotation marks (“ ”).

performanceMonitorInterval

The frequency of gathering performance data. Enter an
integer value for the polling interval, in seconds, for which
you want to capture data. The range of values is 3 to 3600
seconds. The default value is 5 seconds.

performanceMonitorIterations

The number of samples to capture. Enter an integer value.
The range of values for samples captured is 1 to 3600. The
default value is 5.

Additional Information

When you use this command, you can specify one or more of the optional parameters.

286