Save Storage Array SAS PHY Counts

Description

This command saves the storage array SAS physical layer (SAS PHY) counters to a file. To reset the SAS PHY counters,
run the Reset Storage Array SAS PHY Baseline command. See Reset Storage Array SAS PHY Baseline.

Syntax

save storageArray SASPHYCounts file="filename"

Parameters

Parameter

Description

file

Specifies the file path and the file name to which you save
the SAS PHY counters. Enclose the file path and the file
name in double quotation marks (" "). For example: file="C:
\Program Files\CLI\logs\sasphy.csv"
This command does not automatically append a file

extension to the saved file. Any file name is acceptable,

but the .csv extension must be used.

Save Storage Array State Capture

Description

This command saves the state capture to a file.

Syntax

save storageArray stateCapture file="filename"

Parameters

Parameter

Description

file

Name of the file to which to save the state capture. You

must put quotation marks (" ") around the file name.

Save Storage Array Support Data

Description

This command saves the storage array support-related information to a file.