Stop storage array iscsi session, Stop storage array physical disk firmware download – Dell PowerVault MD3260i User Manual

Page 374

Advertising
background image

Parameters

None.

Notes

The controller firmware returns a confirmation that the diagnostic test was cancelled.
In addition, you can start the database configuration diagnostic test through the storage management software GUI;
however, you cannot stop the database configuration diagnostic test through the storage management software GUI. If
you want to stop a running diagnostic test, you must use the stop storageArray configDbDiagnostic
command.
If you try to use the stop storageArray configDbDiagnostic command after validation of the storage array
configuration is complete, you do not receive any message that the validation has finished. This behavior is expected.

Stop Storage Array iSCSI Session

Description

This command forces the termination of an iSCSI session.

Syntax

stop storageArray iscsiSession [sessionNumber]

Parameters

Parameter

Description

sessioNumber

The identifier number of the iSCSI session. Enclose the

identifier number of the iSCSI session in square brackets

([ ]).

Stop Storage Array Physical Disk Firmware Download

Description

This command stops a firmware download to the physical disks in a storage array that was started with the download
storageArray physicalDiskFirmware command. This command does not stop a firmware download that is
already in progress to a physical disk; however, this command stops all firmware downloads to physical disks that are
waiting for the download.

Syntax

stop storageArray physicalDiskFirmwareDownload

374

Advertising