1x8 sas backplane board, Removing the 1x8 sas backplane board – Dell PowerVault DP600 User Manual

Page 121

Advertising
background image

Installing System Components

121

19 Reinstall the center fan bracket. See "Replacing the Center Fan Bracket"

on page 106.

20 Close the system. See "Closing the System" on page 68.
21 Reconnect the system to the electrical outlet and turn on the system and

attached peripherals.

As the system boots, it detects the presence of the new processor and
automatically changes the system configuration information in the
System Setup program.

22 Press <F2> to enter the System Setup program, and check that the processor

information matches the new system configuration. See "Using the
System Setup Program" on page 47
for instructions about using the System
Setup program.

23 Run the system diagnostics to verify that the new processor operates

correctly. See "Running the System Diagnostics" on page 173 for
information about running the diagnostics and troubleshooting
processor problems.

1x8 SAS Backplane Board

Removing the 1x8 SAS Backplane Board

CAUTION:

Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.

1 Remove the front bezel, if attached. See "Removing the Bezel" on

page 64.

2 Turn off the system and attached peripherals, and disconnect the

system from the electrical outlet and peripherals.

3 Open the system. See "Opening the System" on page 67.
4 Disconnect the cables from the SAS controller daughter card on the

expansion bay bracket and remove the cables from the center fan bracket.

book.book Page 121 Monday, September 14, 2009 1:53 PM