Solving Problems Described by LCD Status Messages

When a single message appears on the status LCD, locate the code in
Table 1-6 and perform the suggested corrective action. The code on the LCD
can often specify a very precise fault condition that is easily corrected. For
example, if the code

E0780

MISSING CPU 1

appears, you know that a

microprocessor is not installed in socket 1.

In contrast, you might be able to determine the problem if multiple related
errors occur. For example, if you receive a series of messages indicating
multiple voltage faults, you might determine that the problem is a failing
power supply.

I1911

>3 ERRs Chk

Log

LCD overflow message.

A maximum of three error
messages can display
sequentially on the LCD.
The fourth message displays
as the standard overflow
message.

Check the SEL for details
on the events.

I1912

SEL Full

System Event Log is full of
events, and is unable to log
any more events.

Clear the log by deleting
event entries.

W1228

ROMB Batt <

24hr

Warns predictively that the
RAID battery has less than
24 hours of charge left.

Replace RAID battery.
See "Replacing the SAS
RAID Controller
Daughter Card Battery"
on page 126.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the

"Glossary" on page 215.