Installing System Components

4 Remove the filler plate from the drive slot on the peripheral bay.
5 Disconnect the cables from the SAS controller daughter card on the

expansion-bay bracket and pull the cables out of the way of the center fans.

6 Remove the fans from the center fan bracket. See "Removing and

Installing a Fan" on page 83.

7 Remove the center fan bracket. See "Removing the Center Fan Bracket"

on page 105.

8 If the mounting screws are not attached to the drive, install them now.
9 Insert the new optical drive three-quarters of the way into the drive slot

on the peripheral bay, with the mounting screws entering the bay slide
slots. See Figure 3-16.

10 Attach one end of the ribbon cable to the IDE connector on the system

board (see Figure 6-2) and the other end to the connector on the rear of
the optical drive.

11 Attach the power cable to the CD power connector (CD/TBU) at the

top of the SAS backplane board (see Figure 6-3) and to the power
connector on the rear of the optical drive.

12 Push the optical drive the rest of the way into the bay until the spring latch

engages.

13 Replace the center fan bracket. See "Replacing the Center Fan Bracket"

on page 106.

14 Replace the fans into the center fan bracket.
15 Reconnect the cables to the SAS controller daughter card.
16 Close the system. See "Closing the System" on page 68.
17 Replace the front bezel, if removed in step 2.
18 Reconnect the system and peripherals to their electrical outlets.