23

Table 1-6.

LCD Status Messages

Code

Text

Causes

Corrective Actions

N/A

SYSTEM NAME

A 62-character string that
can be defined by the user in
the System Setup program.

The SYSTEM NAME displays
under the following
conditions:

• The system is powered on.

• The power is off and

active POST errors are
displayed.

This message is for
information only.

You can change the
system string in the
System Setup program.
See "Using the System
Setup Program" on
page 47.

E1000

FAILSAFE,

Call Support

See "Getting Help" on
page 185.

E1114

Temp Ambient

Ambient system temperature
is out of acceptable range.

See "Troubleshooting
System Cooling
Problems" on page 156.

E1116

Temp Memory

Memory has exceeded
acceptable temperature and
has been disabled to prevent
damage to the components.

See "Troubleshooting
System Cooling
Problems" on page 156.

E1210

CMOS Batt

CMOS battery is missing, or
the voltage is out of
acceptable range.

See "Troubleshooting the
System Battery" on
page 154.

E1211

ROMB Batt

RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.

Reseat the RAID battery.
See "Replacing the SAS
RAID Controller
Daughter Card Battery"
on page 126, and
"Troubleshooting System
Cooling Problems" on
page 156.

E12

nn

XX

PwrGd

Specified voltage regulator
has failed.

See "Getting Help" on
page 185.

E1229

CPU # VCORE

Processor # VCORE voltage
regulator has failed.

See "Getting Help" on
page 185.

book.book Page 23 Monday, September 14, 2009 1:53 PM