Dell PowerVault DP600 User Manual

Page 41

Advertising
background image

About Your System

41

No boot sector on

hard drive

Incorrect configuration
settings in System Setup
program, or no operating
system on hard drive.

Check the hard-drive
configuration settings in
the System Setup program.
See "Using the System
Setup Program" on page 47.
If necessary, install the
operating system on your
hard drive. See your
operating system
documentation.

No timer tick

interrupt

Faulty system board.

See "Getting Help" on
page 185.

Northbound merge

error - The

following DIMM has

been disabled by

BIOS: DIMM x

The specified DIMM was
unable to establish a
successful data link with
the memory controller.

See "Troubleshooting
System Memory" on
page 158.

Not a boot diskette

No operating system on
diskette.

Use a bootable diskette.

PCIe Degraded Link

Width Error:

Embedded

Bus#

nn

/Dev#

nn

/Func

n

Expected Link Width

is

n

Actual Link Width is

n

Faulty or improperly
installed PCIe card in the
specified slot.

Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" on
page 87. If the problem
persists, see "Getting Help"
on page 185.

PCIe Degraded Link

Width Error: Slot

n

Expected Link Width

is

n

Actual Link Width is

n

Faulty or improperly
installed PCIe card in the
specified slot.

Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" on
page 87. If the problem
persists, see "Getting Help"
on page 185.

Table 1-7.

System Messages (continued)

Message

Causes

Corrective Actions

book.book Page 41 Monday, September 14, 2009 1:53 PM

Advertising