Dell PowerVault DP600 User Manual

Page 35

Advertising
background image

About Your System

35

support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.

Table 1-7.

System Messages

Message

Causes

Corrective Actions

Alert! Redundant

memory disabled!

Memory configuration

does not support

redundant memory.

Installed memory
modules are not the same
type and size; faulty
memory module(s).

Ensure that all memory
modules are of the same
type and size and that they
are properly installed. See
"Memory" on page 107. If
the problem persists, see
"Troubleshooting System
Memory" on page 158.

Attempting to update

Remote

Configuration.

Please wait...

Remote Configuration
request has been detected
and is being processed.

Wait until the process is
complete.

BIOS Update Attempt

Failed!

Remote BIOS update
attempt failed.

Retry the BIOS update. If
problem persists, see
"Getting Help" on
page 185.

Caution! NVRAM_CLR

jumper is installed

on system board.

NVRAM_CLR jumper is
installed. CMOS has
been cleared.

Remove the NVRAM_CLR
jumper. See Figure 6-1 for
jumper location.

CPUs with different

cache sizes

detected!

Microprocessors with
different cache sizes are
installed.

Ensure that all
microprocessors have the
same cache size and that
they are properly installed.
See "Microprocessor" on
page 117.

Decreasing available

memory

Faulty or improperly
installed memory
modules.

See "Troubleshooting
System Memory" on
page 158.

book.book Page 35 Monday, September 14, 2009 1:53 PM