About Your System

E2111

SBE Log

Disable DIMM

##

The system BIOS has
disabled memory single-bit
error (SBE) logging, and will
not resume logging further
SBEs until the system is
rebooted. "##" represents
the DIMM implicated by the
BIOS.

See "Troubleshooting
System Memory" on
page 158.

E2112

Mem Spare

DIMM ##

The system BIOS has spared
the memory because it has
determined that the memory
had too many errors. "## &
##" represents the DIMM
pair implicated by the BIOS.

See "Troubleshooting
System Memory" on
page 158.

E2113

Mem Mirror

DIMM ## & ##

They system BIOS has
disabled memory mirroring
because it has determined
that one half of the mirror
has had too many errors.
"## & ##" represents the
DIMM pair implicated by
the BIOS.

See "Troubleshooting
System Memory" on
page 158.

E2118

Fatal NB Mem

CRC

One of the connections in
the

Fully Buffered DIMM

(

FBD) memory subsystem

link on the Northbound side
has failed.

See "Troubleshooting
System Memory" on
page 158.

E2119

Fatal SB Mem

CRC

One of the connections in
the FBD memory subsystem
link on the Southbound side
has failed.

See "Troubleshooting
System Memory" on
page 158.

I1910

Intrusion

System cover has been
removed.

Information only.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions