31

E201A

SIO Err

SIO failure.

See "Getting Help" on
page 185.

E201B

Kybd

Controller

Keyboard controller failure.

See "Getting Help" on
page 185.

E201C

SMI Init

System management
interrupt (SMI) initialization
failure.

See "Getting Help" on
page 185.

E201D

Shutdown

Test

BIOS shutdown test failure. See "Getting Help" on

page 185.

E201E

POST Mem

Test

BIOS POST memory test
failure.

See "Troubleshooting
System Memory" on
page 158. If problem
persists, see "Getting
Help" on page 185.

E201F

DRAC Config

Dell remote access controller
(DRAC) configuration
failure.

Check screen for specific
error messages.

Ensure that DRAC cables
and connectors are
properly seated. If
problem persists, see your
DRAC documentation.

E2020

CPU Config

CPU configuration failure.

Check screen for specific
error messages.

E2021

Memory

Population

Incorrect memory
configuration. Memory
population order incorrect.

Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 158.

E2022

POST Fail

General failure after video.

Check screen for specific
error messages.

E2110

MBE DIMM ##

& ##

One of the DIMMs in the set
implicated by "## & ##"
has had a memory multi-bit
error (MBE).

See "Troubleshooting
System Memory" on
page 158.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions