About Your System

29

E1A10

PBD Pwr

Cable

The power distribution
board power cable is
unseated, missing, or bad.

Ensure that the power
distribution board power
cable is seated properly.
If the problem persists,
replace the power
distribution board power
cable. See "Installing the
Power Distribution
Board" on page 142.

E1A14

SAS Cable A

SAS cable A is unseated,
missing, or bad.

Check the cable
connection to the SAS
backplane. See "Cabling
the SAS Backplane
Boards" on page 129.

E1A15

SAS Cable B

SAS cable B is unseated,
missing, or bad.

Check the cable
connection to the SAS
backplane. See "Cabling
the SAS Backplane
Boards" on page 129.

E1A16

SAS Cable FB

Flex bay SAS cable is
unseated, missing, or bad.

Check the cable
connection to the SAS
backplane. See "Cabling
the SAS Backplane
Boards" on page 129.

E1A17

Pwr Cable FB

Flex bay power cable is
unseated, missing, or bad.

Check the power cable
connection to the flex bay
backplane. See "Installing
the 1x2 Flex Bay Drive
Bracket" on page 125.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

book.book Page 29 Monday, September 14, 2009 1:53 PM