Dell PowerVault DP600 User Manual

Page 38

Advertising
background image

38

About Your System

Error: Incorrect

memory

configuration. DIMMs

must be installed in

pairs of matched

memory size, speed,

and technology.

Mismatched or
unmatched DIMMs
installed; faulty or
improperly seated
memory module(s).

Ensure that all pairs of
memory modules are of the
same type and size and that
they are properly installed.
See "Memory" on page 107.
If the problem persists, see
"Troubleshooting System
Memory" on page 158.

Error: Memory

failure detected.

Memory size reduced.

Replace the faulty

DIMM as soon as

possible.

Faulty or improperly
seated memory
module(s).

See "Troubleshooting
System Memory" on
page 158.

!!*** Error: Remote

Access Controller

initialization

failure*** RAC

virtual USB devices

may not be

available...

Remote Access Controller
initialization failure

Ensure that the Remote
Access Controller is
properly installed. See
"Installing a RAC Card" on
page 114.

FBD training error:

The following branch

has been disabled:

Branch x

The specified branch
(channel pair) contains
DIMMs that are
incompatible with each
other.

Ensure that only Dell-
qualified memory is used.
Dell recommends
purchasing memory
upgrade kits directly from
www.dell.com or your Dell
sales agent to ensure
compatibility.

Gate A20 failure

Faulty keyboard
controller; faulty system
board.

See "Getting Help" on
page 185.

Table 1-7.

System Messages (continued)

Message

Causes

Corrective Actions

book.book Page 38 Monday, September 14, 2009 1:53 PM

Advertising