Dell PowerVault DP600 User Manual

Page 25

Advertising
background image

About Your System

25

E1414

CPU #

Thermtrip

Specified microprocessor is
out of acceptable
temperature range and has
halted operation.

See "Troubleshooting
System Cooling Problems"
on page 156. If the problem
persists, ensure that the
microprocessor heat sinks
are properly installed. See
"Troubleshooting the
Microprocessors" on
page 169.

NOTE:

The LCD continues

to display this message
until the system’s power
cord is disconnected and
reconnected to the AC
power source, or the SEL
is cleared using either
Server Assistant or the
BMC Management Utility.
See the Dell OpenManage
Baseboard Management
Controller User’s Guide

for

information about these
utilities.

E1418

CPU #

Presence

Specified processor is
missing or bad, and the
system is in an unsupported
configuration

See "Troubleshooting the
Microprocessors" on
page 169.

E141C

CPU Mismatch

Processors are in a
configuration unsupported
by Dell.

Ensure that your
processors match and
conform to the type
described in the
Microprocessor Technical
Specifications outlined in
your system’s Getting
Started Guide.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

book.book Page 25 Monday, September 14, 2009 1:53 PM