2 connection cables, 6wiring – Pilz PMCprotego D.72/000/0/0/2/208-480VAC User Manual
Page 117

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-9
6.3
Notes on wiring
6
Wiring
6.3.2
Connection cables
Connection cables
6-
][Verdr_Leiterquerschnitte_D_48_72
We recommend the following cable cross sections in accordance with
EN 60204:
* North America: max. 39 m length, Europe: up to max. length
Connection
Pin designation
Device
Cable cross section
Conditions
Mains voltage AC
X0
48 A
72 A
16 mm²
25 mm²
600 V
DC intermediate cir-
cuit
X8
48 A
72 A
25 mm²
25 mm²
1000 V, shielded for
lengths > 500 mm
Brake resistor
X8
48 A
72 A
35 mm²
35 mm²
1000 V, shielded for
lengths > 20 cm
Motor cables
X8
48 A
72 A
16 mm²
25 mm²
600 V, shielded,
C < 150 pF/m
Resolver, thermal
switch, max.50 m*
X2
All
4x2x0.25 mm²
Twisted pair,
shielded, C < 120pF/
m
Encoder, thermal
switch,
Max. 50 m*
X1
All
7x2x0.25 mm²
Twisted pair, shielded
Incremental encoder,
thermal switch,
Max. 25 m
X1
All
8x2x0.25 mm²
Twisted pair, shielded
Analogue inputs, AG-
ND, max 30 m
X3
All
0.25 mm²
Max. 1.5 mm²
Twisted pair, shielded
Digital inputs and out-
puts, BTB, DGND,
max. 30 m
X3
All
0.5 mm²
Max. 1.5 mm²
Holding brake (mo-
tor):
X9A
All
Min. 0.75 mm
Max. 1.5 mm²
600 V, shielded,
check voltage drop
+24 V/XGND, max.
30 m
X3, X4
All
Max. 1.5 mm²
Check voltage drop
Holding brake +24 V,
max. 30 m
X9B
All
Max. 1.5 mm²
Check voltage drop