4.3.2.2
Digital inputs
Digital inputs
4-
][Funktion_Ein_dig_enable_protego_D_48_72
ENABLE (X3A/1)
Functions:
A “1” signal enables the inverted rectifier of the servo amplifier in or-
der to drive the motor.
The enable is only possible if the inputs STO1-ENABLE and STO2-
ENABLE are connected for the safety function in accordance with the
application (see section: "Digital inputs STO1-ENABLE (X4/7), STO2-
ENABLE (X4/5)".
In a disabled condition (“0” signal), the connected motor is torque-
free.
PLC-compatible (IEC 61131-2 Type 1), volt-free, reference earth is
DGND
Further information and connection examples can be found in this chap-
ter under "Safety function STO".
Parameter setting:
A software enable is also required in the commissioning software (log-
ic AND connection).
X3A/6, 7
DIGITAL-
INOUT1
DIGITAL-
INOUT2
2
Semiconductor input
or output
IEC 61131-2
Type 1
4 kHz
Signal output
from pre-pro-
grammed func-
tions
X3B/14, 15
BTO/RTO
1
Relay output
max. 30 VDC,
max. 42 VAC
Operational
readiness
X4/7
STO1-ENABLE 1
Semiconductor input
20 - 30 V
Safety function
STO
1st shutdown
route
safe
X4/5
STO2-ENABLE 1
Semiconductor input
20 - 30 V
Safety function
STO
2nd shutdown
route
safe
X4/8
STO1-STATUS
1
Semiconductor out-
put
24 VDC
Status of safety
function STO1-
ENABLE
X4/6
STO2-STATUS
1
Semiconductor out-
put
24 VDC
Status of safety
function STO2-
ENABLE
Connectors/
terminals
Designation
Number
Type
Signal range
Scan rate
Application