32 index 1c32 sm output parameter – BECKHOFF EP9214-0023 User Manual

Page 93

Advertising
background image

Comissioning and Configuration

4.6.2.2.32

Index 1C32 SM output parameter

Index

Name

Meaning

Data type

Flags

Default

1C32:0

SM output
parameter

Synchronization parameters for the outputs

UINT8

RO

0x20 (32

dec

)

1C32:01

Sync mode

Current synchronization mode:

• 0: Free Run

• 1: Synchronous with SM 2 event

• 2: DC-Mode - Synchronous with SYNC0

Event

• 3: DC-Mode - Synchronous with SYNC1 event

UINT16

RW

0x0000 (0

dec

)

1C32:02

Cycle time

Cycle time (in ns):

• Free Run: Cycle time of the local timer

• Synchronous with SM 2 event: Master cycle

time

• DC-Mode: SYNC0/SYNC1 Cycle Time

UINT32

RW

0x000F4240 (1000000

dec

)

1C32:03

Shift time

Time between SYNC0 event and output of the out-
puts (in ns, DC mode only)

UINT32

RO

0x00000384 (900

dec

)

1C32:04

Sync modes
supported

Supported synchronization modes:

• Bit 0 = 1: free run is supported

• Bit 1 = 1: Synchronous with SM 2 event is

supported

• Bit 2-3 = 01: DC mode is supported

• Bit 4-5 = 10: Output shift with SYNC1 event

(only DC mode)

• Bit 14 = 1: dynamic times (measurement

through writing of 1C32:08)

UINT16

RO

0x0001 (1

dec

)

1C32:05

Minimum
cycle time

Minimum cycle time (in ns)

UINT32

RO

0x000F4240 (1000000

dec

)

1C32:06

Calc and
copy time

Minimum time between SYNC0 and SYNC1 event (in
ns, DC mode only)

UINT32

RO

0x00000000 (0

dec

)

1C32:07

Minimum
delay time

UINT32

RO

0x00000384 (900

dec

)

1C32:08

Command

• 0: Measurement of the local cycle time is

stopped

• 1: Measurement of the local cycle time is

started

The entries 1C32:03, 1C32:05, 1C32:06, 1C32:09,
1C33:03, 1C33:06, and 1C33:09 are updated with the
maximum measured values.
For a subsequent measurement the measured values
are reset

UINT16

RW

0x0000 (0

dec

)

1C32:09

Maximum
delay time

Time between SYNC1 event and output of the out-
puts (in ns, DC mode only)

UINT32

RO

0x00000384 (900

dec

)

1C32:0B

SM event
missed
counter

Number of missed SM events in OPERATIONAL (DC
mode only)

UINT16

RO

0x0000 (0

dec

)

1C32:0C

Cycle ex-
ceeded
counter

Number of occasions the cycle time was exceeded in
OPERATIONAL (cycle was not completed in time or
the next cycle began too early)

UINT16

RO

0x0000 (0

dec

)

1C32:0D

Shift too
short
counter

Number of occasions that the interval between
SYNC0 and SYNC1 event was too short (DC mode
only)

UINT16

RO

0x0000 (0

dec

)

1C32:20

Sync error

The synchronization was not correct in the last cycle,
(outputs were output too late; DC mode only)

boolean

RO

0x00 (0

dec

)