A.6.2 traffic unit redundancy configuration, A.6.3 redundant unit redundancy configuration – Comtech EF Data CLO-10 User Manual

Page 102

Advertising
background image

CLO-10 Link Optimizer

Revision 1

Redundant System Operation

MN/CLO-10.IOM

A.6.2 Traffic Unit Redundancy Configuration

Each Traffic Unit must have its Redundancy enabled and must be assigned a Traffic Unit Number that
corresponds to the number labeld on the High Speed Bus (HSB) cable connector. The Redundancy
screen is as shown:

Redundancy: En/Dis

Assign(#XX)

Select En/Dis or Assign (#XX) using the ◄ ► arrow keys. The user should then press ENTER.

If En/Dis is selected:

Redundancy En/Dis:

Enabled Disabled

This selection activates or deactivates redundancy operation for the unit. Select Enable or Disable
using the ◄ ► arrow keys. The user should then press ENTER.

If Assign (#XX) is selected:

Redundancy Assign:

CLO-10 #XX

The currently assigned number for the unit(#01 through #12) will be displayed. Assign the unit
number for placement within a 1:N redundancy system by using the ▲ ▼ arrow keys to select
#01 through #12.. The user should then press ENTER.

IMPORTANT

The unit’s assignment number must match that of the numbered DB-25
connector on the High Speed Bus cable (CEFD P/N CA/RB0014-XX-U2).

A.6.3 Redundant Unit Redundancy Configuration

When configuring a Redundant CLO-10, the Redundancy screen displays as follows:

Red: En/Dis Holdoffs

Active Auto(OFF) Manual


Select En/Dis, Holdoffs, Active, Auto, or Manual using the ◄ ► arrow keys. The user should
then press ENTER.

Note: Auto (OFF/ON) indicates the current staus of the Operating Mode (automatic or manual
operating mode
).