Comtech EF Data CLO-10 User Manual

Page 119

Advertising
background image

CLO-10 Link Optimizer

Revision

1

Remote Control

MN/CLO-10.IOM

B.6.1

Switch Remote Commands and Queries for the CLO-10 Link Optimizer

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for

Command or

Response to

Query

Description of Arguments

Response

to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query

(Target to

Controller)

Operating Mode

OPM=

1 byte

Command or Query.

‘x’ indicates the operating mode, where:

0 = manual mode
1 = auto mode

OPM=
OPM?
OPM*
OPM#
OPM^
OPM@

OPM? OPM=x




Bridged or Back-
up Unit Number



BBU=

3 bytes

Command or Query.

The bridge/back-up state, followed by the selected TU to be
acted on:

x is 0 = bridge
1 = backup (only possible when in manual mode)
yy is 01:12 for traffic unit number

BBU=
BBU?
BBU*
BBU#
BBU^
BBU@

BBU? BBU=xyy

Active Units

ACT=

12 bytes

Command or Query.

‘x’ indicates the active state of all 12 traffic units, where:

0 = de-activate traffic unit (except in back-up)
1 = activate traffic unit

ACT=
ACT?
ACT*
ACT#
ACT^
ACT@

ACT? ACT=xxxxxxxxxxxx

(see description of
arguments)

Active Unit Query

N/A

12 bytes

Query only.

‘x’ Indicates the state of all 12 traffic units, where:

0 = TU not Activated
1 = TU activated but not responding
2 = TU activated and responding

AUQ=
AUQ?
AUQ*
AUQ#
AUQ^
AUQ@

AUQ? AUQ=xxxxxxxxxxxx

(see description of
arguments)

Backup Holdoff
Time

BKH=

3 bytes

Command or Query.

The backup holdoff time is the delay when auto mode prepares
to backup a faulted traffic unit.

BKH=
BKH?
BKH *
BKH #
BKH ^
BKH@

BKH? BKH

=xxx

(see description of
arguments)

B-7

Advertising