B.6.4 bulk commands and queries – Comtech EF Data CLO-10 User Manual

Page 131

Advertising
background image

CLO-10 Link Optimizer

Revision

1

Remote Control

MN/CLO-10.IOM

B-19

Parameter

Type

Command

(Instruction

Code and

qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query
(Target to Controller)

Temperature of
the Base Unit

N/A 4

bytes

Query

only.

Unit returns the value of the internal base unit
temperature, in the form of sxxx (degrees C), where:
s=sign (+ or – character)
xxx=value

Example: ITP=+127

N/A ITP?

ITP=sxxx

(see description of
arguments)

B.6.4

Bulk Commands and Queries

Parameter

Type

Command

(Instruction

Code and

qualifier)

Arguments

for Command

or Response

to Query

Description of arguments

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query

(Target to Controller)

Global
Configuration

MGC= 80

bytes,

with

numerical
entries, fixed
values and
delimiters

Command or Query.

The format is:
MGC=uuuu.uuuudddd.ddddrrrr.rrrrbbbbbfffggghhhemm
mmmmmmmmcaa.atxxxxxxxxxxxxxxxxxxxxxx, where:

MGC=
MGC?

MGC*

MGC#

MGC^

MGC?

MGC?n

MGC=uuuu.uuuudddd.ddd
drrrr.rrrrbbbbbfffggghhhem
mmmmmmmmmcaa.atxxxx
xxxxxxxxxxxxxxxxxx

Where n=0 to 9

Returns the MGC portion of
1 of 10 stored
configurations

(see description of
arguments)

uuuu.uuuu=Uplink Frequency
dddd.dddd=Downlink Frequency
rrrr.rrrr=Remod Frequency
bbbbb=Bandwidth Command
fff=CnC Frequency Offset
ggghhh=CnC Search Delay
e=External Reference Clock
mmmmmmmmmm=Unit Alarm Mask
c=Remod Output Control
aa.a=Remod Output Attenuation
t=Unit Test Mode (Read only)
xxxxxxxxxxx = reserved
xxxxxxxxxxx = reserved

same as UFQ
same as RFQ
same as TFQ
same as BWC
same as CCF
same as CSD
same as ERF
same as MSK
same as TXO
same as TAT
same as TST
reserved
reserved



Advertising