CLO-10 Link Optimizer

Revision

1

Remote Control

MN/CLO-10.IOM

B.6.3

Commands and Queries

Parameter

Type

Command

(Instruction

Code and

qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query
(Target to Controller)

Equipment ID



N/A 6

bytes

Query

only.

Unit returns information concerning the equipment
identification and the option field in the form: aaabcd,
where:

aaa=defines the model number (CLO-10 in this case)
aaa=010 for CLO-10

b=Defines Bandwidth Options:
1=2048 MHz
2=4096 MHz
3=8192 MHz
4=10000 MHz
c,d reserved

Example: EID=010200 means CLO-10 with 2048 Mhz
option, c,d reserved (c,d always set to 0,0)

N/A EID?

EID=aaabcd

(see description of
arguments)

Unit ID

N/A

4 bytes

Query only.

Unit returns information concerning the base unit
identification and the option field in the form: abcdefg,
where:

a=IF Mhz
1=70/140 MHz

b,c,d reserved
b,c,d always set to 0,0,0

N/A UID?

UID=abcd
(see description of
arguments)