Comtech EF Data CLO-10 User Manual

Page 121

Advertising
background image

CLO-10 Link Optimizer

Revision

1

Remote Control

MN/CLO-10.IOM

B.6.2

Remote Commands and Queries For the CLO-10 Link Optimizer

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for

Command or

Response to

Query

Description of Arguments

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query

(Target to

Controller)

Uplink Frequency

UFQ=

9 bytes

Command or Query.

50 to 90/100 and 180 MHz (70/140 MHz units)
Resolution = 100 Hz

Example: UFQ=0070.0000

UFQ=
UFQ?
UFQ*
UFQ#
UFQ^
UFQ@

UFQ? UFQ=xxxx.xxxx

(see description of
arguments)

Downlink
Frequency

RFQ=

9 bytes

Command or Query.

50 to 90/100 and 180 MHz (70/140 MHz units)
Resolution = 100 Hz

Example: RFQ=0070.0000

RFQ=
RFQ?
RFQ*
RFQ#
RFQ^
RFQ@

RFQ? RFQ=xxxx.xxxx

(see description of
arguments)

Remod Frequency

TFQ=

9 bytes

Command or Query.

50 to 90 and 100 to 180 MHz (70/140 MHz units)
Resolution=100 Hz

Example: TFQ=0070.0000

TFQ=
TFQ?
TFQ*
TFQ#
TFQ^
TFQ@

TFQ? TFQ=xxxx.xxxx

(see description
arguments)

Remod Output
Enable




TXO

1 byte value.
0, 1

Command or Query.

1 = Enable the remodulation output
0 = Disable the remodulation output

Example: TXO=1 – Turn the remodulation output on

TXO=
TXO?
TXO*
TXO#
TXO^
TXO@

TXO TXO=x

Remod Output
Attenuation

TAT

1 byte value.
0 to 31.5 dB

Command or Query.

0 to 31.5 dB output attenuation in 0.5 dB steps


Example: TAT=25.5

TAT=
TAT?
TAT*
TAT#
TAT^
TAT@

TAT TAT=xx.x

B-9

Advertising