Comtech EF Data CLO-10 User Manual
Page 123

CLO-10 Link Optimizer
Revision
1
Remote Control
MN/CLO-10.IOM
B-11
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command or
Response to
Query
Description of Arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
Carrier-in-Carrier
(CnC) Search
Delay
CSD=
6 bytes
Command or Query.
CnC Search Delay consists of two parameters:
Link Delay and Delay Range.
Link Delay 000 ms to 330 ms
Delay Range 000 ms to 025 ms
Search Delay Range = Link Delay +/- Delay Range
Search Delay Min = Link Delay - Delay Range
Search Delay Max = Link Delay + Delay Range
This command will be rejected if any combination of the above
two parameters results in a Search Delay Max that is > 330
ms or a Search Delay Min < 0 ms.
Syntax: CSD=xxxyyy
Where: xxx=Link Delay yyy=Delay Range
Example: 100020
Where Link Delay=100 ms and Delay Range=20 ms
Resulting search delay min = 80 ms
Resulting Search Delay max = 120 ms
To set a search delay Min of 0 ms and Max = 30 ms:
Example: 015015
Where Link Delay=015 ms and Delay Range=015 ms
Resulting search delay min = 000 ms
Resulting Search Delay max = 030 ms
To set a search delay Min of 280 ms and Max = 330 ms:
Example: 305025
Where Link Delay=305 ms and Delay Range=025 ms
Resulting search delay min = 280 ms
Resulting Search Delay max = 330 ms
CSD=
CSD?
CSD*
CSD#
CSD^
CSD@
CSD? CSD=xxxyyy
(see description of
arguments)
External
Reference
Frequency
ERF=
1 byte, value
of 0 through 4
and 7
Command or Query.
External Reference Frequency, where:
0=Internal, external reference connector not used
1=External 1 MHz
2=External 2 MHz
3=External 5 MHz
4=External 10 MHz
7=External auto detect(1,2,5 or 10 MHz)
Example: ERF=0 (External reference not used, uses Internal)
ERF=
ERF?
ERF*
ERF#
ERF^
ERF? ERF=x
(see description of
arguments)