Comtech EF Data CLO-10 User Manual

Page 123

Advertising
background image

CLO-10 Link Optimizer

Revision

1

Remote Control

MN/CLO-10.IOM

B-11

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for

Command or

Response to

Query

Description of Arguments

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query

(Target to

Controller)

Carrier-in-Carrier
(CnC) Search
Delay

CSD=

6 bytes

Command or Query.

CnC Search Delay consists of two parameters:
Link Delay and Delay Range.
Link Delay 000 ms to 330 ms
Delay Range 000 ms to 025 ms
Search Delay Range = Link Delay +/- Delay Range
Search Delay Min = Link Delay - Delay Range
Search Delay Max = Link Delay + Delay Range

This command will be rejected if any combination of the above
two parameters results in a Search Delay Max that is > 330
ms or a Search Delay Min < 0 ms.

Syntax: CSD=xxxyyy
Where: xxx=Link Delay yyy=Delay Range

Example: 100020
Where Link Delay=100 ms and Delay Range=20 ms
Resulting search delay min = 80 ms
Resulting Search Delay max = 120 ms
To set a search delay Min of 0 ms and Max = 30 ms:

Example: 015015
Where Link Delay=015 ms and Delay Range=015 ms
Resulting search delay min = 000 ms
Resulting Search Delay max = 030 ms
To set a search delay Min of 280 ms and Max = 330 ms:

Example: 305025
Where Link Delay=305 ms and Delay Range=025 ms
Resulting search delay min = 280 ms
Resulting Search Delay max = 330 ms

CSD=
CSD?
CSD*
CSD#
CSD^
CSD@

CSD? CSD=xxxyyy

(see description of
arguments)

External
Reference
Frequency

ERF=

1 byte, value
of 0 through 4
and 7

Command or Query.

External Reference Frequency, where:

0=Internal, external reference connector not used
1=External 1 MHz
2=External 2 MHz
3=External 5 MHz
4=External 10 MHz
7=External auto detect(1,2,5 or 10 MHz)

Example: ERF=0 (External reference not used, uses Internal)

ERF=
ERF?
ERF*
ERF#
ERF^

ERF? ERF=x

(see description of
arguments)

Advertising