B-18

Parameter

Type

Command

(Instruction

Code and

qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query
(Target to Controller)

CnC Delay
Monitor

N/A 5

bytes

Query

only.

Monitors the estimated delay value of the interferer in
milliseconds.

Example 1: CLO=229.5 (229.5 ms)

N/A CDM?

CDM=xxx.xxx
(see description of
arguments)

CnC Freq Offset
Monitor

N/A 6

bytes

Query

only.

Monitors the estimated frequency offset between
desired and interferer will be calculated.
Unit is in kilohertz ( kHz).

Example 1: CFM=+001.0 (1 kHz)
Example 2: CFM=9999.9 (CnC not locked)

N/A CFM?

CFM=xxxx.x
(see description of
arguments)

Software Revision

N/A

34-37 bytes

Query only.

Unit returns the value of the internal software revision
installed in the unit, in the form:
Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z
or
Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz

N/A SWR?

SWR=Boot:x.y.zz
Bulk1:x.y.zz Bulk2:x.y.zz
(see description of
arguments)

Software
Information

N/A variable Query

only.

Complete unit software information:
Example: FRW=

Boot:
FW/xxxxx-1- 1.1.1 04/30/07
Bulk1:
FW/11245- 1.1.1 11/11/04
FW/11247-1- 1.1.1 11/11/04
Bulk2:
FW/11245A 1.1.1 11/11/04
FW/11247-1A 1.1.1 11/11/04

N/A FRW?

FRW=x…x
(see description of
arguments)

Software Image

IMG=

1 byte, value
of 1 or 2

Command or Query.

Current active software image, where:
1=Bulk Image #1 currently active
2=Bulk Image #2 currently active

IMG=
IMG?

IMG*

IMG#

IMG^

IMG? IMG=x

(see description of
arguments)

Serial Number of
Base Unit

N/A 9

bytes

Query

only.

Used to query the 9-digit serial number of the unit in the
form: xxxxxxxxx

N/A SNM?

SNM=xxxxxxxxx
(see description of
arguments)

Advertising