Comtech EF Data CLO-10 User Manual

Page 128

Advertising
background image

CLO-10 Link Optimizer

Revision 1

Remote Control

MN/CLO-10.IOM

B-16

Parameter

Type

Command

(Instruction

Code and

qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query
(Target to Controller)

Faults and Status

N/A

12 bytes

Query only.

Unit returns the current highest-prority fault and status
codes for the Unit (hardware), Uplink Traffic, Downlink
Traffic, and Remod in the form abcdef, where:

a=Unit Faults:
0=No Faults
1=Power Supply Fault, +5 volts
2=Power Supply Fault, +12 volts
3=Power Supply Fault, -12 volts
4=Reference PLL Fault
5=RU Configuration Error Fault
6= Loss Of CnC Lock Alarm
7=Ext Reference Clock Alarm
8=RU Traffic Unit Communication Timeout Alarm
9=RU Traffic Unit Error Alarm
a=RU Traffic Unit Invalid Configuration Alarm
the rest are reserved for future expansion

Items 5, 8 and 9 apply to Redundant Unit mode

b=Uplink Status:
0=Uplink OK
1=1

st

LO Synthesizer Lock Fault

2=2nd LO Synthesizer Lock Falut
3=Reference AGC Out Of Range Alarm
the rests are reserved for future expansion

c=Downlink Status:
0=Downlink OK
1=1

st

LO Synthesizer Lock Fault

2=2nd LO Synthesizer Lock Fault
3=AGC Out Of Range Alarm
the rests are reserved for future expansion

d=Remod status:
0= REMOD OK
1=1

st

LO Synthesizer Lock Fault

2=2nd LO Synthesizer Lock Fault

N/A FLT?

FLT=abcdef
(see description of
arguments)

e=Change in fault status
since last poll.

f=Change in unit
configuration since last
poll

(see description of
arguments)

Advertising