A.5.4 adding and removing clo-10s and/or modules – Comtech EF Data CLO-10 User Manual

Page 99

Advertising
background image

CLO-10 Link Optimizer

Revision 1

Redundant System Operation

MN/CLO-10.IOM

A.5.4 Adding and Removing CLO-10s and/or Modules

► To add an additional CLO-10:

Step

Procedure

1

Attach all cables as outlined in A.3 CABLES AND CONNECTIONS.

2

Configure the modem and Optimizer as outlined in Chapter 4. MODEM AND
OPTIMIZER CONFIGURATION.




Figure A-12. Module Removal/Installation

► To remove a faulted Traffic Unit that is not being backed up:

Step

Procedure

1

De-activate the unit from the configuration.

2

Secure the module to the chassis using the (two) captive thumb screws.

3

Loosen the captive thumb screws securing the IOSM to the CLO-10 chassis. Do
not unplug the cable connections.

4

Remove the module from the chassis slot by sliding the module straight out until
it is clear of the chassis. See

Figure A-15.

NOTE: It is recommended that the unit being serviced is pushed a few inches
towards the front of the rack/cabinet in order to provide slack for the installed
HSB cable, thus easing removal of the still-cabled module.

A–15