7 iec line input (ac power) connector, 8 dc power connector – Comtech EF Data CLO-10 User Manual

Page 47

Advertising
background image

CLO-10 Link Optimizer

Revision 1

Rear Panel Connectors

MN/CLO-10.IOM

3–5

3.7

IEC Line Input (AC Power) Connector

The IEC line input connector contains the ON/OFF switch for the unit. It is also
fitted with two fuses, one each for line and neutral connections (or L1, L2, where
appropriate). These are contained within the body of the connector, behind a
small plastic flap.

A standard, detachable, non-locking, 3-prong power cord (IEC plug) supplies the
Alternating Current (AC) power to the CLO-10. Observe the following:

AC Power Specifications

Input Power

75W maximum, less than 65W typical

Input Voltage

100 - 240 volts AC, +6/-10% - autosensing
(total absolute max. range is 90 to 254 VAC)

Connector Type

IEC

Fuse Protection

• For 230 volt AC operation, use T2.5A, (slow-blow)

20mm fuses.

• For 115 volt AC operation, use T5.0A, (slow-blow)

20mm fuses.



3.8

DC Power Connector

A standard 3-screw terminal block supplies the Direct Current (DC)
power to the CLO-10. Observe the following:





IMPORTANT

For continued operator safety, always replace the fuses
with the correct type and rating.

DC Power Specifications

Input Power

200W maximum, less than 50W typical

Input Voltage

36 to 72 VDC; 6.25 amps

Connector Type

Terminal Block

Fuse Protection

3.15A Slow-blow
20mm type fuses

IMPORTANT

For continued operator safety, always replace the fuses with
the correct type and rating.

Advertising