6.4.5 CONFIG: Remod (Remodulation Parameters)

Remod: Frequency On/Off

Attenuation (◄ ► ENT)

Select Frequency, On/Off, or Attenuation using the ◄ ► arrow keys, then press

ENTER

.

CONFIG: Remod ÆFrequency

If Frequency is selected:

Remod: Frequency

0070.0000 MHz (◄ ► ▲ ▼ ENT)

Edit the IF Remod Frequency by selecting the digit to be edited, using the W X arrow keys. The
value of the digit is then changed using the ST arrow keys. The range of frequencies is 50-90
MHz and 100-180 MHz with 100 Hz resolution.

Once the IF Remod Frequency is edited, the user should press

ENTER.

CONFIG: Remod Æ On/Off

If On/Off is selected:

Output State: Off On

(◄ ► ENT)

Edit the Output State for this unit. Select either On or Off using the W X arrow keys, then press

ENTER

.

CONFIG: Remod Æ Attenuation

If Attenuation is selected:

Attenuation:

00.0 dB (◄ ► ▲ ▼ ENT)

Edit the Attenuation for this unit. Editing the value is accomplished by selecting the digit to be
edited, using the W X arrow keys. The value of the digit is then changed using the ST arrow
keys. The range varies 0-31.5 dB in 0.5 dB steps.

Once the Attenuation is edited, the user should press

ENTER

.