Comtech EF Data CLO-10 User Manual

Page 125

Advertising
background image

CLO-10 Link Optimizer

Revision

1

Remote Control

MN/CLO-10.IOM

B-13

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for

Command or

Response to

Query

Description of Arguments

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query

(Target to

Controller)

IP Address

IPA=

18 bytes
numerical

Command or Query.

Used to set the IP Address and network prefix for the 10/100
BadeTX Ethernet management port, in the format:

xxx.xxx.xxx.xxx.yy, where:

yy is the network prefix (0 to 31)

Example: 010.006.030.001.24

IPA=
IPA?
IPA*
IPA#

IPA? IPA=xxx.xxx.xxx.xxx

.yy
(see description of
arguments)

Configuration
Save

CST=

1 byte

Command only.

Causes the CLO-10 to store the current unit configuration
(common functions and all four slots) in Configuration Memory
location defined by the 1-byte argument (0 to 9)

Example: CST=4 (store the current configuration in location 4)

CST=
CST?
CST*
CST#
CST^

N/A N/A

Configuration
Load

CLD=

1 byte

Command only.

Causes the CLO-10 to retrieve a previously stored unit
configuration (common functions and all four slots) in
Configuration Memory location defined by the
1-byte argument ( 0 to 9)

Example: CLD=4 (retrieve unit configuration from location 4)

CLD=
CLD?
CLD*
CLD#
CLD^

N/A N/A

RTC Date

DAY=

6 bytes

Command or Query.

A date in the form ddmmyy, where:

dd=day of the month (01 to 31)
mm=month (01 to 12)
yy=year (00 to 99)

Example: DAY=240457 (April 24, 2057)

DAY=
DAY?
DAY*
DAY#
DAY^

DAY? DAY=ddmmyy

(see

description of
arguments

RTC Time

TIM=

6 bytes

Command or Query.

A time in the form hhmmss, indicating the time from midnight,
where:

hh=hours (00 to 23)
mm=minutes (00 to 59
ss=seconds (00 to 59)

Example: TIM=231259 (23 hours, 12 minutes, 59 seconds)

TIM=
TIM?
TIME*
TIM#
TIM^

TIM? TIM=

hhmmss

(see

description and
arguments)

Advertising