6 hssi data connections, 7 lvds data connections, 8 ethernet data connections – Comtech EF Data CRS-300 User Manual

Page 100: T. 4.4.3.6), T. 4.4.3.8)

Advertising
background image

CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Cables and Connections

Revision 19

4–26

4.4.3.6 HSSI Data Connections

If HSSI is the driving traffic data type (see Figure 4-9 and Figure 4-10):

First, connect the Control/Data Cable CA/WR0066 (for control/data purposes) between the

Redundant CDM-625/A and the Switch RMI (see Sect. 4.4.3.1).

Next, do these steps to connect and secure the Control Cable CA-0000069 (HD-15M to DB-9M,

6’) between the Switch TMI(s) and the Traffic CDM-625/A(s):

HD-15F connector labeled “J1” on the Switch TMI(s), to

DB-9F connector labeled “1:1 Control” on the Traffic CDM-625/A(s).

Then, do these steps to connect and secure the Control Cable CA/WR9189-6 (HD-50M  HD-

50M, 6’) (for data purposes) between the Switch TMI(s) and Traffic CDM-625/A(s):

50-pin Type ‘HD’ HSSI (SCSI-II) female connector labeled “HSSI” on the Switch TMI(s), to

50-pin Type ‘HD’ HSSI (SCSI-II) female connector on the CIC-60 Adapter Module, to

DB-25F connector labeled “Data Interface” on the Traffic CDM-625/A(s).

4.4.3.7 LVDS Data Connections

If LVDS is the driving traffic data type (see Figure 4-9, Figure 4-11, and Figure 4-12):

First, connect the Control/Data Cable CA/WR0066 (for control/data purposes) between the

Redundant CDM-625/A and the Switch RMI (see Sect. 4.4.3.1).

Then, do these steps to connect and secure the Control/Data Cable CA/WR0066 (for data

purposes) between the Switch TMI(s) and Traffic CDM-625/A(s):

DB-25M connector labeled “P1” on the Switch TMI(s), to

DB-25F connector labeled “Data Interface” on the Traffic CDM-625/A(s).

4.4.3.8 Ethernet Data Connections

1)

When you use the CDM-625/A in Dedicated Management Ethernet Port mode,

this disables all four of the offline modem’s Ethernet ports unless you configure

one of the four ports as the ‘Dedicated Management Port.’ For more

information, see Sect. 5.4.13.3 CONFIG: IP Setup in the CDM-625 or

CDM-625A Advanced Satellite Modem Installation and Operation Manuals.

2)

When you use Ethernet (with no Sub-Mux) as the dedicated data interface for

the redundancy system, you must use the wired-thru method, explained in

Sect. 4.4.3.8.1, to make all cabling connections.