Switch Connectors and Pinouts

Revision 19

3–16

3.3 CRS-300 Chassis Ground and Power Connections

3.3.1 Chassis Ground Interfaces

CAUTION – PROPER GROUNDING PROTECTION IS REQUIRED. THE INSTALLATION

INSTRUCTIONS REQUIRE THAT YOU MUST ENSURE THE INTEGRITY OF THE

PROTECTIVE EARTH AND THAT YOU MUST MAINTAIN THE EQUIPMENT’S

CONNECTION TO THE PROTECTIVE EARTH AT ALL TIMES.

THE CRS-300 IS DESIGNED FOR CONNECTION TO A POWER SYSTEM THAT HAS

SEPARATE GROUND, LINE, AND NEUTRAL CONDUCTORS. THE EQUIPMENT IS NOT

DESIGNED FOR CONNECTION TO A POWER SYSTEM THAT HAS NO DIRECT

CONNECTION TO GROUND. IT IS THEREFORE IMPERATIVE DURING INSTALLATION,

CONFIGURATION, AND OPERATION THAT YOU PROPERLY GROUND THE UNIT USING

THE GROUND STUD PROVIDED ON THE REAR PANEL OF THE UNIT.

(TOP) CRS-240 (AC) Power Supply Module

(BOTTOM) CRS-250 DC Power Supply Module

Figure 3-3. CRS-300 Chassis Ground Interfaces

Use the #10-32 stud, located adjacent to the power interface on the CRS-230 or CRS-250 Power

Supply Module (Figure 3-1), for connecting a common chassis ground among equipment.

The AC power interface provides the safety ground.