Comtech EF Data CRS-300 User Manual

Page 226

Advertising
background image

CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Serial-based Remote Product Management

Revision 19

7–10

Parameter Type

Command

(Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numerical codes,

that is, ASCII codes between 48 and 57)

Response to Command

(Target-to-Controller)

Query

(Code and

qualifier)

Response to query

(Target-to-Controller)

Config Load

CLD=

1 byte, numerical,

0 to 9

Command only.

Forces the Switch to retrieve the Configuration Memory

location defined by the argument (0 to 9) and to re-program

the Switch with that stored configuration.

CLD= (message OK)

CLD? (received OK, but

invalid arguments found)

CLD* (message OK, but the

memory location does not

contain configuration info)

N/A

N/A

Config Store

CST=

1 byte, numerical,

0 to 9

Command or Query.

The command forces the Switch to store the its current

configuration in Configuration Memory location defined by

the argument (0 to 9).
Example: CST=4 (Store current configuration in location 4)

WARNING: Use with caution!

If the location already

contains data, it will be automatically overwritten. If in doubt,

query the location first. The query returns the contents of

the location.

CST= (message OK)

CST? (received OK, but

invalid arguments found)

CST# (message OK, but

only permitted in Remote

mode)

CST?n

where n is

0 to 9

Returns the same format

as the SGC, with the

form:

CST=xxx....xxx for a

valid config, and

CST* where no valid

config is found

Date

DAY=

6 bytes, numerical Command or Query.

The date, in the form ddmmyy (international date

convention), where:

dd = day of the month, between 01 and 31,

mm = month of the year, between 01 and 12, and

yy = year, between 97 and 96 (1997 to 2000, then 2000 to

2096)
Example: DAY=240457 would be April 24, 2057.

DAY= (message OK)

DAY? (received OK, but

invalid arguments)

DAY# (message OK, but

only permitted in Remote

mode)

DAY?

DAY=ddmmyy

(see Description of

Arguments)

Equipment ID

N/A

4 bytes,

alphanumeric

Query only.

Unit returns information concerning the equipment

identification.
Example: S300

N/A

EID?

EID=xxxx

(see Description of

Arguments)

Advertising