C.2 modem setup – Comtech EF Data CRS-300 User Manual

Page 295

Advertising
background image

CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Appendix C

Revision 19

C–11

C.2 Modem Setup

Local Modem m

, where m is modem position number (1 through 10) on Switch:

o MCA = (Switch RCA) + (100 x m)

o Set EDMAC Framing on.

o Set as EDMAC master.

o Set with EDMAC Slave Address Range, ESA = (Modem RCA) + 10

Distant Modem 1

(attached to the Distant end of link to Modem m):

o Remote control address: no setting required (Remote control not used).

o Set EDMAC Framing on.

o Set as an EDMAC slave.

o Set Slave Address, ESA = (Master ESA) + 1

o MCA = ESA

Two Distant Modems

in a 1:1 configuration:

Set up the on-line modem as for Distant Modem 1, described previously in this section. The

offline modem is automatically configured to match the on-line modem. M&C can only be

achieved to the online modem.

Note: It is not possible for the offline modem of a 1:1 pair to respond to EDMAC messages

directly as it is not transmitting. Using the internal 1:1 link, the online modem polls and

retains the off-line modem status. Depending on the modem, this information can be

obtained as follows:

1)

For CDM-625/A, CDM-570/A, CDM-570L/AL, and CDM-600/L modems:

Use OUS (Offline Unit Status) – OUS? for queries. This command/query is available in

the following modems/firmware versions:

Modem

FW Version

Modem

FW Version

CDM-625A

1.1.1 or later

CDM-570

1.4.1 or later

CDM-625

1.1.1 or later

CDM-570L

1.3.1 or later

CDM-570A

1.1.1 or later

CDM-600

1.6.1 or later

CDM-570AL

1.1.1 or later

CDM-600L

1.3.0 or later

Advertising