CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Serial-based Remote Product Management

Revision 19

7–14

Parameter Type

Command

(Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numerical codes,

that is, ASCII codes between 48 and 57)

Response to Command

(Target-to-Controller)

Query

(Code and

qualifier)

Response to query

(Target-to-Controller)

Switch Alarm

Mask

SAM=

1 byte, numerical

Command or Query.

Where x indicates the Switch alarm mask:

0 = no faults masked

1 = PSU-A faults masked

2 = PSU-B faults masked

SAM= (message OK)

SAM? (received OK, but

invalid arguments found)

SAM# (message OK, but

only permitted in Remote

mode)

SAM?

SAM=x

(see Description of

Arguments)

SwitchDataTime

SDT=

1 byte, numerical

Command or Query.

This command allows the Switch to send commands to all

attached modems o n a d aily bas is t o s et t heir t ime an d

date values to the same as the Switch. This value is also

saved i n nonv olatile memory t o r etain s etting during a

power outage. The factory default setting is SDT=0.
SwitchDataTime, where x where:

0 turns off this feature.

1 enables this feature
Example: SDT=1

SDT= (message OK)

SDT? (received OK, but

invalid arguments)

SDT* (message OK, but not

permitted in current mode)

SDT?

SDT=xx

(see Description of

Arguments)

Switch Global

Configuration

SGC=

29 bytes,

numerical

Command or Query.

Global configuration of the Switch, in the form:

OaaaaaaaaaaBNNbbrrMSAssssssss, where:

O = Operating Mode – same as OPM (1 bytes)

a = Active Modems – same as ACT (10 bytes)

B = Bridge/Backup State – same as BBU (1 byte)

N = Selected TM Number - same as BBU (2 bytes)

b = Backup Holdoff Time – same as BKH (2 byte)

r = Restore Holdoff Time – same as RSH (2 byte)

M = Modem Alarm Mask – same as MAM (1 byte)

S = Switch Alarm Mask – same as SAM (1 byte)

A = Audio Alarm Mask – same as AAM (1 bytes)

P = Priority mode – same as PRI

s = 7 spare bytes

SGC= (message OK)

SGC? (received OK, but

invalid arguments found)

SGC# (message OK, but

only permitted in Remote

mode)

SGC?

SGC=OaaaaaaaaaaBNN

bbrrMSAPsssssss

(see Description of

Arguments)

Switch ID

SID=

24 bytes, ASCII

Command or Query.

A user-defined Switch ID, which is a fixed length of 24

characters.
Valid characters include:

Space ( ) * + - , . / 0-9 and A-Z.

SID= (message OK)

SID? (received OK, but

invalid arguments found)

SID# (message OK, but

only permitted in Remote

mode)

SID?

SID=xxxxxxxxxxxxxxxxx

xxxxxxx

(see Description of

Arguments)