CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Cables and Connections

Revision 19

4–43

HD-15F connector labeled “J1” on the Switch RMI or TMI(s), to

HD-15F connector labeled “J9 Auxiliary” on the SLM-5650/5650A.

4.6.3 Traffic Data Connections – CRS-300 to Modems

Referring to Figure 4-16:

If HSSI is the traffic data type, do these steps to connect and secure the HSSI Data Cable

CA/WR9189-6 between the Switch and each SLM-5650/5650A:

HSSI (HD-50F) connector labeled “J2” on the Switch RMI or “J3” on the Switch TMI(s), to

HSSI (HD-50F) connector labeled “J7 HSSI” on the SLM-5650/5650A.

If EIA-530/-232 is the traffic data type, do these steps to connect and secure the Control/Data

Cable CA/WR0066 (for data purposes) between the Switch and each SLM-5650/5650A:

DB-25M connector labeled “P2” on the Switch RMI, or “P1” on the Switch TMI(s), to

DB-25F connector labeled “J6 EIA530” on the SLM-5650/5650A.

Referring to Figure 4-17:

If Balanced G.703 is the traffic data type, do these steps to connect and secure the

CA/WR9038-1 cable between the Switch and each SLM-5650/5650A:

DB-15M connector labeled “P1” on the Switch RMI or TMI(s), to

DB-15F connector labeled “J1 Bal Data” on the SLM-5650/5650A.

If Unbalanced G.703 is the traffic data type, do these steps to connect and secure the pair of

BNC PL/0813-8 cables between the Switch and each SLM-5650/5650A:

BNC connectors labeled “J4 Tx” on the Switch RMI, or “J3 Tx” on the Switch TMI(s), to BNC

connectors labeled “J3 Rx” on the SLM-5650/5650A, and

BNC connectors labeled “J3 Rx” on the Switch RMI, or “J5 Rx” on the Switch TMI(s), to BNC

connectors labeled “J2 Tx” on the SLM-5650/5650A.